Working Instruction:

Download Sample Test Result & Test Chart:

  • Click the photo to zoom in
  • Click the photo to zoom in

Details Introduction & our Strength

The PV520A series of ultrasonic component analyzers (Impedance Analyzer) are jointly developed by the Department of Automation of Tsinghua University and the Institute of Acoustics of the Chinese Academy of Sciences. They are used as comprehensive solutions for the detection of piezoelectric ultrasonic devices and equipment.
PV520A is a new generation of ultrasonic component analyzer developed on the basis of PV70A-P (computer version) and PV70A-D (built-in display version), combining the advantages of the former two. Its characteristics are as follows:
1. The large screen and full-screen touch make PV520A have the operating experience of PV70A-P (computer version) without the cumbersome feeling of computer operation.
2. Relying on the new super powerful ARM processor data processing capability, the measurement accuracy of PV520A is much higher than that of PV70A-D (with display version), which can reach the level of PV70A-P (computer version).
3. The full-screen touch operation is more user-friendly, and there is no need for a large number of physical buttons of the PV70A-D (built-in display version), so the operation of the instrument becomes extremely simple, at the same time the product size is smaller, the weight is lighter, and the portability is better.
4. It can be connected to a computer for operation like PV70A-P, and the software is fully compatible, so users no longer need to be familiar with software operations.
Four major advantages of the product:
Testing equipment is an important part of product quality control, so the “credibility” of the product is very important. Our products have four major advantages:

1. Technology jointly developed by Tsinghua University and the Institute of Acoustics of the Chinese Academy of Sciences.

2. It has been 15 years since our PV60A/70A series products were introduced to the market in 2001. They have been used by thousands of customers in the industry and have become the de facto ultrasonic industry measurement standards.

3. Over the past 15 years, more than two hundred university research institutes have used our instruments, because university research institutes often have more than 200,000 imported Agilent instruments 4294A. Our instruments have been tested against imported Agilent instruments countless times. Yes, the facts prove that the test results of our instrument are completely credible.

4. Our instruments have been selected by many German and American ultrasound application companies as test instruments. The instrument is the key to the quality of the product. If you choose an instrument made in China, it must be built on the basis of full trust.

For ultrasonic measurement, the two graphs of admittance circle and logarithmic graph are important (the two graphs are the main methods for judging qualified), and more than ten parameters: resonance frequency Fs, large conductance Gmax, bandwidth F2 -F1, anti-resonance frequency Fp, quality factor Qm, free capacitance CT, dynamic resistance R1, dynamic inductance L1, dynamic capacitance C1, static capacitance C0, effective electromechanical coupling coefficient Keff. The PV520A series of ultrasonic component analyzers are suitable for measuring various ultrasonic devices, including: piezoelectric ceramics, transducers, ultrasonic cleaning machines, ultrasonic plastic welders, hydroacoustics, magnetostrictive materials, ultrasonic pulverizers, ultrasonic atomization , Ultrasonic dental cleaning, reversing radar, ultrasonic ranging, phacoemulsification, ultrasonic descaling, ultrasonic motors, and all other devices and equipment that use piezoelectric and ultrasonic.

Widely used (industry approved)
Our products have been used in the following units: Tsinghua University Physics Department, Peking University Electronics Department, Shanghai Jiaotong University Instrument Engineering Department, Zhejiang University, Huazhong University of Science and Technology, Harbin Institute of Technology, Tianjin University, South China University of Technology, Tongji University, Xi’an Jiaotong University , Department of Physics, Shaanxi Normal University, Institute of Acoustics, Chinese Academy of Sciences, 715 China Shipbuilding Industry Corporation, China Shipbuilding Industry Corporation and a large number of Chinese companies, as well as some from Japan, Germany, France, the United States, Italy, Taiwan, Hong Kong, South Korea Some companies. Therefore, the total number of units using our products has exceeded a thousand.

Details & Specifications

Preformation Type: PV520A-S Type: PV520A-T Type: PV520A-V
Feature Portable, 7.8″ touch screen Portable, 7.8″ touch screen Portable, 7.8″ touch screen
Size: length: 24cm, Width: 19cm
front height: 5cm, back height: 10cm
length: 24cm, Width: 19cm
front height: 5cm, back height: 10cm
length: 24cm, Width: 19cm
front height: 5cm, back height: 10cm
Frequency range 1KHz~1MHz 1KHz~3MHz 1KHz~5MHz
Measuring target 1) Resonance frequency Fs
2) Maximum conductance Gmax
3) Half power points F1 and F2
4) Anti-resonance frequency Fp
5) Mechanical quality factor Qm
6) Free capacitance CT
7) Dynamic resistance R1
8) Dynamic inductance L1
9) Dynamic capacitance C1
10) Static capacitance C0
11) Effective electromechanical coupling coefficient Keff
12) Plane electromechanical coupling coefficient Kp
13) Free dielectric constant
Total 21 type of test result parameter & Graph.
1) Resonance frequency Fs
2) Maximum conductance Gmax
3) Half power points F1 and F2
4) Anti-resonance frequency Fp
5) Mechanical quality factor Qm
6) Free capacitance CT
7) Dynamic resistance R1
8) Dynamic inductance L1
9) Dynamic capacitance C1
10) Static capacitance C0
11) Effective electromechanical coupling coefficient Keff
12) Plane electromechanical coupling coefficient Kp
13) Free dielectric constant
Total 21 type of test result parameter & Graph.
1) Resonance frequency Fs
2) Maximum conductance Gmax
3) Half power points F1 and F2
4) Anti-resonance frequency Fp
5) Mechanical quality factor Qm
6) Free capacitance CT
7) Dynamic resistance R1
8) Dynamic inductance L1
9) Dynamic capacitance C1
10) Static capacitance C0
11) Effective electromechanical coupling coefficient Keff
12) Plane electromechanical coupling coefficient Kp
13) Free dielectric constant
Total 21 type of test result parameter & Graph.
Basic accuracy +/-0.04%  +/-0.04%  +/-0.02%
Frequency accuracy ±10ppm ±10ppm ±10ppm
Phase resolution 0.15° 0.15° 0.15°
Test environment temperature 10~40℃ 10~40℃ 10~40℃
Test speed 5 sec/one (1000point sweeping) 5 sec/one (1000point sweeping) 5 sec/one (1000point sweeping)
Impedance Range 1Ω~1MΩ 1Ω~1MΩ 1Ω~1MΩ
Frequency Step 0.1Hz~Any 0.1Hz~Any 0.1Hz~Any
Power supply AC100V~AC250V,50~60Hz, 30W AC100V~AC250V,50~60Hz, 30W AC100V~AC250V,50~60Hz, 30W
 

Details & Specifications

Daily use in factory

Video Introduction and How to use Impedance Analyzer

Impedance Analyzer PV520A General Introduction
Impedance Analyzer to test Piezoceramic Chips
Impedance Analyzer to test Transducer /Converter

* Contact our sales expert for more information, such as Details Spec. User’s Guide book, tech support, and etc.